What a board is usually responsible for

Most condo and townhouse associations split each fireplace in two. The owner holds what sits inside the unit: the firebox, the doors, the damper, any gas logs. The association holds what runs through shared walls or sits above the roof: the flue in a common wall, the stack or framed chase, the chase cover, the cap and the flashing. Any fireplace in a clubhouse, lobby or pool room belongs to the association outright. The governing documents draw the exact line, and it varies from one community to the next.

That split matters when a resident calls to say the fireplace smokes. If the cause is a broken cap or a chase cover rusted through, the fix is the board's. If it is a damper stuck halfway, it is usually the owner's. Our report places each finding by location so the manager can match it to the documents.

  • Usually the owner's: firebox, damper, glass doors, gas logs, hearth
  • Usually the association's: shared flue walls, the stack or chase, chase cover, cap, flashing
  • Always the association's: fireplaces in common rooms
  • The documents have the final word on any part

Shared stacks and smoke in the wrong unit

In two and three story buildings, several fireplaces often vent through one chase or one masonry stack. When the flue tops sit close together, smoke leaving one can be drawn down into the next on a still evening. Residents describe it as a neighbor's fire they can smell in their own living room. The fix is usually at the top: taller terminations, a divider, or caps set to keep exhaust apart.

We test draft at each fireplace we inspect and note which flues share a stack. Where one unit's complaint points at a common part, the report says which part and why, so the board can act on the stack as a whole rather than one unit at a time.

A record the board can keep

Every fireplace gets its own sheet: unit number, type of fireplace, what we checked, the draft result and each finding with a photo and a Stop, Schedule or Monitor label. On top sits a summary table for the whole property, one row per fireplace, that fits in a board packet. Next year's inspection follows the same layout, so the board can see what changed.

Access is planned with the manager before the visit. Residents get a notice with the date, and we work through the units in an order that keeps roof trips to a minimum. Units we could not enter are listed as not inspected, so the record is honest about its gaps.

Per fireplace pricing

The visual check is priced per fireplace, so the total is simple arithmetic. Camera work and sweeping are added only for the flues that need them.

Visual check, each fireplace
$57
Camera inspection for a flue that calls for one
$405
Sweeping a flue with heavy buildup
from $435

Repairs to common parts such as caps, chase covers and flashing are quoted in writing for the board, separate from the inspection.

Questions from boards and managers

Do we need a camera inspection on every flue?

No. Most buildings start with the visual check on every fireplace. We recommend a camera run only where the visual check or a resident's complaint gives a reason, and we list those flues with the price before doing any.

A resident says smoke comes in from next door. Is that ours?

Often it is, because the cause usually sits at the shared stack or chase. We test the draft in both units and look at the tops, then the report says which part is at fault.

Who receives the report?

The manager or board contact who books. Unit sheets can be sent to individual owners if the board asks for that.

What happens with units nobody opens for us?

They are listed as not inspected in the summary. We can return for them on a second date at the same per fireplace price.

Do you inspect gas fireplaces in the units?

Yes. A gas fireplace gets the same per fireplace check, with attention to the vent, the glass seal and signs of poor burning such as soot on the glass.